HLA and KIR SSP typing
HISTO TYPE SSP / KIR TYPE SSP

Fast HLA typing for smaller sample volumes and confirmatory tests? Look forward to extremely simple handling with HISTO TYPE SSP Kits. It is considered a robust and well established solution for low-resolution typing based on sequence-specific primers.

  • Reliable: Robust against fluctuations in DNA concentration.
  • Convenient: user-friendly HISTO MATCH software for evaluation and documentation for all loci
  • Easy to implement: only basic PCR laboratory equipment needed (thermocyler and gel electrophoresis)

Thanks to the CE -certified and validated Taq polymerase, HISTO TYPE SSP sets quality standards.

 

The KIR TYPE SSP Kit allows genotyping of 14 Killer cell Immunoglobulin-like Receptor (KIR) genes plus 2 pseudogenes. It gives additional information on possible disparities between KIR and the respective HLA ligands in the context of transplantation.

proven and robust
  • TEST-KITS
  • WORKFLOW
  • ACCESSORIES
  • DOWNLOADS
  • FAQ
  • Product
  • Bundle
  • REF
  • CE-Certification
  • Compatibility
  • HISTO TYPE A low
    incl. 1x Happy Taq Polymerase, 23 PCR Mixe + Contamination control
  • 20 tests
  • 70721
  • IVDD
  • HISTO TYPE ABC
    incl. 4x Happy Taq Polymerase, 95 PCR Mixe + Contamination control
  • 20 Tests
  • 7102
  • IVDD
  • HISTO TYPE ABDR
    incl. 4x Happy Taq Polymerase, 95 PCR Mixe + Contamination control
  • 20 Tests
  • 7098
  • IVDD
  • HISTO TYPE B low
    incl. 2x Happy Taq Polymerase, 47 PCR Mixe + Contamination control
  • 20 tests
  • 70731
  • IVDD
  • HISTO TYPE B*57:01 / B*51
    Classic SSP incl. 1x Happy Taq Polymerase, 7 Mixe + Contamination control
  • 20 tests
  • 70715
  • IVDD
  • HISTO TYPE B27 low
    Classic SSP incl. 1x Happy Taq Polymerase, 1 PCR Mix
  • 48 tests
  • 7070
  • IVDD
  • HISTO TYPE B27 low
    Classic SSP incl. 1x Happy Taq Polymerase, 1 PCR Mix
  • 96 tests
  • 7071
  • IVDD
  • HISTO TYPE C low
    incl. 1x Happy Taq Polymerase, 23 PCR Mixe + Contamination control
  • 20 tests
  • 70741
  • IVDD
  • HISTO TYPE Coeliac Disease
    incl. 1x Happy Taq Polymerase, 23 PCR Mixe + Contamination control
  • 20 tests
  • 70941
  • IVDD
  • HISTO TYPE DQB low
    incl. 1x Happy Taq Polymerase, 8 PCR Mixe + Contamination control
  • 20 Tests
  • 70891
  • IVDD
  • HISTO TYPE DR low
    incl. 1x Happy Taq Polymerase, 24 PCR Mixe + Contamination control
  • 20 Tests
  • 70751
  • IVDD
  • HISTO TYPE DR/DQB
    incl. 2x Happy Taq Polymerase, 32 PCR Mixe + Contamination control
  • 20 Tests
  • 7103
  • IVDD
  • HISTO TYPE Narcolepsy
    Classic SSP incl. 1x Happy Taq Polymerase, 8 PCR Mixe + Contamination control
  • 20 tests
  • 70716
  • IVDD
  • KIR TYPE
    20 PCR Mixe
  • 10 Tests
  • 7105
  • IVDD
  • Product
  • Bundle
  • REF
  • CE-Certification
  • Compatibility
  • CYCLER CHECK
    Kit for verifying the temperature accuracy and uniformity of thermocyclers
  • 10 tests
  • 71044
  • -
  • CYCLER CHECK
    Kit for verifying the temperature accuracy and uniformity of thermocyclers
  • 4 tests
  • 7104
  • -
  • Happy Taq
    Taq Polymerase for use with HISTO TYPE and BAGene SSP kits
  • 250 U (50 µl)
  • 70976
  • -
  • Wipe test
    Contamination control
  • 40 tests
  • 7091
  • -
  • Product Flyer
    Studies / Publications / White Paper

    No FAQs created for this product yet! Would you like to create a FAQ suggestion?

    HISTO TYPE SSP - in disease associations and pharmacogenomics

    Benefit from our simple SSP solutions for specific clinical applications related to HLA alleles.

    Coeliac disease

    Coeliac disease is strongly associated with the DQA1*05:01- DQB1*02:01 and DQA1*03-DQB1*03:02 haplotype. Additionally, DRB1*03, DRB1*07 and DRB1*11 alleles can be used as genetic markers.

    Morbus Bechterew et al.

    Seronegative arthritic diseases like Morbus Bechterew, Morbus Reiter and post infectious reactive arthritis are strongly associated with HLA B*27. Determination of the presence of HLA B*27 is a valuable tool in the diagnosis of these diseases.

    Narcolepsy

    98 % of the Caucasian narcolepsy patients carry the DRB1*15:01- DQA1*01:02-DQB1*06:02 haplotype.

    Abacavir hypersensitivity

    Some patients develop a hypersensitivity reaction against the antire- troviral drug abacavir which is used e.g. for HIV therapy. This hypersensitivity is associated with the allele HLA B*57:01

    KIR TYPE

    KIR typing is used as complimentary diagnostic before bone marrow transplantations and for immunogenetic studies. The KIR TYPE kit enables genotyping of 14 KIR genes and 2 pseudogenes.

    Icon Benefit Box
    YOUR BENEFITS
    • cost effective because of kit format with Happy Taq Polymerase included
    • reliable results - Happy Taq Polymerase is CE certified and validated
    • free user-friendly HISTO MATCH software for evaluation and documentation
    • easy to implement because only basic PCR lab equipment is needed
    Dr. Kristin Launhardt
    Product Manager HLA Diagnostics
    Scientific Liaison Manager
    +49 6404 925-223
    Kristin Launhardt, Product Manager HLA Diagnostics
    Beginn eines Zitats

    HISTO TYPE SSP is the rapid HLA typing based on sequence-specific primers. The kits are optimal for smaller quantities and confirmation tests at low resolution. Easy evaluation is provided by the user-friendly HISTO MATCH software.

    Abschluss eines Zitats

    Cost-effective controls for optimal conditions

    CYCLER CHECK - Temperature on trial

    Regular checks and calibrations of your thermal cyclers are required by EFI and ASHI guidelines. The CYCLER CHECK, which is adapted to our SSP kits, tests the complete 96-well thermoblock for critical deviations in denaturation and annealing temperature. Rely on the easy and cost-effective verification of the temperature accuracy and uniformity of your thermal cycler.

    Wipe test for quality assurance

    Regular wipe tests are mandatory according to the EFI and ASHI guidelines. The use of the wipe test avoids false positive reactions and thus ensures the quality of your results!
    Our wipe test offers you a reliable and fast method to check for contamination with amplicons of the HLA class I and class II genes as well as with genomic DNA in the laboratory.

    Copyright 2024. All Rights Reserved.

    May we offer cookies to you?

    By clicking "Accept all", you agree to cookies being stored on your local device, according to the requirements of the GDPR. This improves navigation on the site, video content can be displayed and we can anonymously analyse whether the pages are being used as intended.

    user_privacy_settings

    Domain name: bag-diagnostics.com
    Expiry: 30 days
    Storage location: Localstorage
    Description: Saves the privacy level settings from the Cookie Consent Tool "Privacy Manager".

    user_privacy_settings_expires

    Domain name: bag-diagnostics.com
    Expiry: 30 days
    Storage location: Localstorage
    Description: Stores the retention period of the privacy level settings from the Cookie Consent Tool "Privacy Manager".

    home_anim

    Domain name: bag-diagnostics.com
    Expiry: -
    Storage location: Localstorage
    Description: Saves how often the animation of the start page has run. It is no longer displayed after x runs.

    selectedQuestionNumber

    Domain name: bag-diagnostics.com
    Expiry: -
    Storage location: Localstorage
    Description: Saves the position in a questionnaire on certain landing pages

    PHPSESSID

    Domain name: bag-diagnostics.com
    Expiry: After end of session
    Storage location: Cookies
    Description: Stores technically necessary information about the current session

    csrf_https-contao_csrf_token

    Domain name: bag-diagnostics.com
    Expiry: After end of session
    Storage location: Cookies
    Description: Created to block CSFR attack on the current session.
    You are using an outdated browser. The website may not be displayed correctly. Close